SafeTest mode can be deactivated by following the procedure below.
This method is designed to disable all devices on the same circuit simultaneously.
At the distribution board you will need to turn the breaker on and off in the detailed sequence.
| 1 | Ensure power is connected to the unit and that the battery has at least 20% charge. |
| 2 | Switch the power OFF and ON Seven times (i.e. 7 power cycles). Start with a 20-second OFF period, then leave 3 seconds between each switch. A phone timer can assist with timing accuracy. |
| OFF 20 sec | ON 3 sec | OFF 3 sec | OFF 3 sec | ON 3 sec | OFF 3 sec | ON 3 sec | ON 3 sec | OFF 3 sec | ON 3 sec | OFF 3 sec | ON 3 sec | OFF 3 sec |
| TOTAL: 52 SECONDS | ||||||||||||
| 3 | Once the power cycles are complete, the unit will disable safetest |
Comments
0 comments
Article is closed for comments.